Settings, view and help

This chapter is the reference for the program settings (Tools ‣ Settings), the language and the licence, the View and Help menus, updates, error reports and the keyboard shortcuts.

The Settings dialog

Tools ‣ Settings opens the dialog Settings with three tabs: General, Extended settings and Training categories (see Training zones and predictions). OK applies the changes, Cancel discards them. No setting requires a restart.

The settings are saved for your Windows user account. The test shown remains open; after OK, it is reloaded so that curves, thresholds and zones follow the new settings. Only after a change of the data directory is the view empty, because the test belongs to the old database.

If you change the lactate constants or the fixed lactate thresholds, Ergonizer recalculates the results for the group analysis in the background after you close the dialog.

General

Automatically check for updates when program starts

On by default. Ergonizer checks for a new version when it starts and shows a notice in the status bar if one is available, see Updates.

Automatically search for previous year’s examination (Year-o-Matic)

On by default. As the comparison test, Ergonizer takes the test of about one year earlier (11 to 13 months); if there is none, the most recent other test of the same type of ergometry. See Tests and measurement entry.

Differentiated training zones also for Hobby athletes

Off by default: new tests of recreational athletes get a single training zone. With the option, they get the preferred training scheme, see Training zones and predictions.

Data directory

The folder with the database, see Import, export and backups.

COM-Port for Lactate Scout

The serial port of a Lactate Scout+ connected by cable (default COM4), see Tests and measurement entry.

Directory for backups

The folder for the automatic backups. If the field is empty, the folder backup in the data directory is used. See Import, export and backups.

Automatic backup:

How often Ergonizer backs up the database when the program closes: Never, Daily, Weekly (default) or Monthly. See Backups.

Keep at most:

The number of backups kept of each type (1–99, default 10).

Restore defaults

Resets the entries of this tab; the data directory remains unchanged. The changes are saved with OK.

Extended settings

The tab Extended settings is a list of categories that you can expand; Open all expands or collapses all of them. Restore defaults resets the tab (except the e-mail and folder settings). Defaults are given in brackets.

General Settings

  • Automatically load last test on restart (off)

  • Address input necessary (on) – street and city are required for new subjects, see Subjects and groups.

  • Percentiles for race cyclists according to age groups (UCI) (on), see Training zones and predictions.

  • Correction of training zones for uncertain lactate threshold (on) – the default for new tests, see Lactate curve and results.

  • Default treadmill slope (1.5 %) for new treadmill tests.

  • Default fixed treadmill slope for uphill running (5 %, in the selected slope unit) for new uphill running tests with a fixed slope.

  • RPE scale from 1 to 10 (default: 6 to 20)? (off) – Borg scale 6–20 or CR10.

PDF settings

  • Open PDF reader automatically (off)

  • Enable PDF by email (depending on the licence), with SMTP server, user name, password, port (587) and Copy of the findings email to. See Lactate curve and results. The password – like a proxy login – applies only to the Windows account under which it was saved; after moving to another account or computer, enter it again.

Standard display (graph of ergometry data)

Defaults for new tests: Show IAT (on), Show Dmax (Cheng et al.) (off), Show Dmax (mod.) (off), Show IAT acc. to Stegmann (off) and the post-exercise course (on). Show fixed lactate thresholds in the plot (off) applies to all tests at once. Grid lines in the lactate chart can be switched on separately for the screen and the printout.

Specifications for the Power Profiles (CP)

  • Remove CP curve limits in the toolbar (experimental) (off)

  • Default settings for the evaluation: the points that are always listed in the panel Maximum predictions from the power profile, each with type of exercise, kind of value (speed, power, duration or distance), value and an additional text. See Critical Power and power profile.

Extended print settings

Print on the 1st page

Performance and heart rate at the IAT (on), Preferred method for IAT (IAT), Power output at FTP (60”) (off), Max. power over 20min (MMP@20min) (on), Dmax and modified Dmax (off), percentile (on), \(\dot{V}\mathrm{O}_{2}\mathrm{max}\) (on), \(\dot{V}\mathrm{La}_{\mathrm{max}}\) (off) and the power normalized to 78 kg body mass (off).

Show on the 2nd report page (table)

V̇O₂max prediction (on), Race Performance Predictions (on).

Percentiles on the printout (on)

Percentiles on pages 1 and 2 of the report and in the summary table (page 4), see Training zones and predictions.

Report length

Ask about report length before printing (off) and Always print (complete or short report), see Lactate curve and results.

Further options

Calculated power for running tests (on), summary table (page 4) when more than two tests are selected, Integrate Power Profile (CP) into the printout (with the CP module), Show training zones and Print training zones (on), MAS (1,600m running pace on grass) (off).

Fixed lactate thresholds

Two lactate concentrations per type of ergometry at which Ergonizer reports the power – by default 2 and 3 mmol/L, for running, canoe, cross trainer, fencing and swimming 2 and 4 mmol/L. Both values must lie between 1.5 and 5.0 mmol/L, and the first must be lower than the second. The rowing field test has its own category (Rowing field test, 2.0 and 3.0 mmol/L); roller skiing and uphill running use the values of the treadmill.

Lactate constants

The default Lactate constant for the IAT per type of ergometry: 1.5 mmol/L, for the cycle ergometer 1.0 mmol/L. The canoe ergometer and the canoe field test have separate values. Existing settings and tests keep their values; the defaults apply to new installations and after Restore defaults. See Tests and measurement entry and Informations sur le diagnostic métabolique de la performance.

Units of measurement

  • Height and weight: kg/cm or lb/ft/in.

  • Speed and distance: km/h, m/s or mph; km, yards or miles; pace per 1,000 m or per mile.

  • Slope: % or degrees.

  • Default treadmill slope for new treadmill tests (1.5 %), and the default fixed speed for new uphill running tests (8 km/h).

  • Energy expenditure: kcal, kJ or MET.

For speed, slope and height/weight you can separately allow choosing the unit individually for each test.

Sports and disciplines

Load sports from external Excel file (off) replaces the list of sports and disciplines by an Excel file.

Language

Tools ‣ Language switches the user interface between Deutsch, English, Français, Italiano, Nederlands, Español and Magyar. Ergonizer then restarts automatically. The report is printed in the language of the user interface. When Ergonizer is started for the first time, it uses the Windows language, or English if that language is not available.

Ergonizer 6 keeps its own language setting; at the first start, it takes over the language of Ergonizer 5 if one was chosen there.

The language also determines the thousands separator: a comma in English (1,000), a space in most other languages (1 000). The decimal separator is always a point. Dates, however, follow the regional format of Windows (its default format for your region), independent of the language of the user interface.

Unlock code and licence

Ergonizer is activated with a 16-character code. If no valid code is stored, the dialog Ergonizer unlock code appears when Ergonizer starts. To enter a new code later, for example after extending your licence, choose Tools ‣ Change unlock code (Ctrl+U). Spaces are ignored, and lower case is converted to upper case. After a valid code, Ergonizer restarts. If you mistype the code and cancel, your stored licence remains unchanged.

If a code is rejected, Ergonizer shows The unlock code was not accepted. Compare it character by character with the code you received; a letter O is turned into the digit 0 as you type.

If a licence covers only versions up to a certain date and the payment for a newer version is still open, Payment not yet received appears when you start that version. It is activated once the payment has been received, which may take a few days to be recorded.

Help ‣ About Ergonizer shows the licensee, the serial number and, for time-limited licences, the remaining time. The modules of your licence (for example Critical Power, glucose, RPE) show in the functions available.

Logo, letterhead and address on the report and in the User information panel come from your licence data; they can only be changed by Ergonizer Software.

Trial version

The trial version is a separate installation (Ergonizer 6 Demo) with its own data directory and settings. If it finds no database at the first start, it creates the sample data without asking (40 subjects, 66 tests, 5 groups). It runs for 30 days from the first start; splash screen and About dialog show the end date, and afterwards the splash screen shows The trial period has expired. Restrictions:

  • at most 2 subjects and 6 tests of your own (the supplied sample data do not count);

  • the sample data can be viewed and evaluated, but not changed or deleted, see Subjects and groups and Tests and measurement entry;

  • no race predictions, no e-mail dispatch, no updates;

  • the note “For demo purposes only” on charts and printouts, and a placeholder letterhead.

View menu

The View menu shows toolbars and panels that have been closed: Toolbars, Quick help panel (Ctrl+K), Data panel (the results panel), Licensee (Ctrl+T) and CP curve and Test selection and results overview (Ctrl+R). Columns of the results overview… chooses the columns of this overview. To hide a panel, click × in its title bar. Toggle statusbar shows or hides the status bar. See Working with Ergonizer.

Help menu

User manual (F1)

Opens this manual at manuals.ergonizer.com in your web browser.

Data sheet (PDF) (Ctrl+Shift+D)

Opens a blank one-page form for recording the measurements by hand during a test: subject data, protocol and a table for power, lactate, heart rate, blood pressure, RPE and cadence. Print it before the test.

Check for update (Ctrl+Shift+U)

See Updates.

About Ergonizer

Version, licence and copyright, with links to the Ergonizer homepage, the shop for updates and an e-mail inquiry.

Updates

Help ‣ Check for update checks online for a newer version. If there is one, the update dialog shows the installed and the new version; Start update downloads the update, starts the installer and closes Ergonizer. See also Installation d’Ergonizer.

Updates are free of charge during the update period of your licence (grace period); during this period, the update dialog shows the remaining days. If it has expired, the dialog says so and links to the shop for the language of the user interface. The update file is stored in a folder of its own in the local application data directory. Ergonizer starts it only if it carries the Ergonizer signature. If the download or this check fails, Ergonizer reports The update could not be downloaded..

With Automatically check for updates when program starts (see General), Ergonizer checks regularly in the background. If an update is available, the status bar shows Update available: …; click it to open the update dialog.

Error reports

If Ergonizer did not close properly, it asks at the next start whether to send an error report to Ergonizer Software. Nothing is sent without your confirmation. More information lists what the report contains: program version and operating system, licence identification, type and location of the error and, after a crash, a technical snapshot of the program state. In rare cases, this snapshot may contain fragments of data being edited (for example the name or date of birth of a subject) and file paths with the Windows user name. The server also stores the IP address. The reports are used only to fix errors and are not passed on; your database is not transferred. See section 8.3 of the licence agreement.

Send report (preselected) sends the report encrypted; Do not send deletes the pending reports. The IT department of a clinic can switch off sending for the whole computer; the question then no longer appears, and the reports stay on the computer.

Keyboard shortcuts

Shortcut

Command

Ctrl+D

File ‣ New subject

Ctrl+B

File ‣ Edit subject

Ctrl+L

File ‣ Delete subject

Ctrl+M

File ‣ New test

Ctrl+O

File ‣ Open/Edit test

Ctrl+P

File ‣ Print

Ctrl+G

File ‣ Generate PDF

Ctrl+Alt+S

File ‣ Save CP curve (on the Power Profile tab)

Ctrl+U

Tools ‣ Change unlock code

Ctrl+K

View ‣ Quick help panel

Ctrl+T

View ‣ Licensee

Ctrl+R

View ‣ Test selection and results overview

Ctrl+H

Rebuild the Test selection and results overview and dock it at the bottom

F1

Help ‣ User manual

Ctrl+Shift+D

Help ‣ Data sheet (PDF)

Ctrl+Shift+U

Help ‣ Check for update

The usual editing keys, such as Ctrl+C and Ctrl+V, work directly in text fields and tables. Outside text fields, Ctrl+C copies the Test selection and results overview.

For the keys in the table of measured values, see Tests and measurement entry.