Lactate curve and results
The Lactate curve tab is the central view of Ergonizer. This chapter describes the chart, the results panel, the thresholds, the smoothing of the curves, the comparison with earlier tests, and the report with print, PDF and e-mail.
The Lactate curve tab
The chart shows the open test:
Lactate (red, left axis 0–16 mmol/L) and heart rate (blue, right axis 60–220 bpm). The measured values are shown as squares; the names of the curves are written at their ends.
The x-axis shows power or speed, depending on the type of ergometry. A second x-axis at the top can show the relative power (W/kg) for tests in watts or the calculated power (W) for running tests.
Thresholds are marked by dashed vertical lines with a ring on the curve and on the x-axis, labelled for example IAT, LT or Dmax (see Thresholds).
Training zones appear as translucent coloured bands behind the curves, see Training zones and predictions.
With the post-exercise course switched on, the recovery values appear to the right of the maximum power on a grey background, with a separate time axis (dashed curves).
Excluded lactate outliers are shown as grey squares marked Outlier, see Tests and measurement entry.
Glucose and RPE have their own tabs, see Working with Ergonizer.
Working with the chart
- Mouse pointer
A vertical line follows the mouse. An info box shows power, heart rate and lactate at this position – one row per test if comparison tests are shown. The status bar shows the same values.
- Right-click
Copy values under the cursor copies the values at the mouse position as a table, for example to paste them into Excel. On a lactate point, the menu also offers Exclude from the curve as an outlier or Reinstate outlier.
- Zone boundaries
Drag a boundary between two training zones with the mouse to move it; Ergonizer recalculates when you release it.
- Zoom
Use the zoom field (50–300 %) and Zoom in / Zoom out in the functions toolbar.
The results panel
The results panel on the left shows, from top to bottom:
the subject (collapsed) with personal data, body weight, height, BMI and training age;
the test with its Test results: the thresholds with power, relative power, pace and heart rate, the values at the fixed lactate concentrations and the maximum values (for example \(P_\mathrm{max}\), HRmax, \(\dot{V}\mathrm{O}_{2}\mathrm{max}\), maximum lactate and \(\dot{V}\mathrm{La}_{\mathrm{max}}\));
depending on the test, predictions, recommended training loads and percentiles, see Training zones and predictions;
Additional settings with the settings described below.
Every change in the results panel is saved immediately, and the evaluation is recalculated.
Additional settings
These settings apply to the open test and are saved with it:
- Adjust curve smoothing
The smoothing of the curves, see Curve smoothing.
- Outlier
Exclude outliers from the curve switches the exclusion of lactate outliers on or off, see Tests and measurement entry. The switch is only here if the test has neither the note Implausible lactate values nor stored exclusions. With the note, it is directly below the note’s text; without the note but with stored exclusions, it is in a section Outlier of its own at the top of the results panel. The panel is rebuilt after switching, so the switch can change its place. Tests without lactate have no switch.
- Adjust lactate constant
The lactate constant of the test; Auto restores the default from the settings.
- Post-exercise values
Shows the recovery course in the chart.
- Show in chart
Switches for the thresholds shown in the chart: IAT, LT, Stegmann threshold, Dmax and modified Dmax (Dmax and modified Dmax exclude each other). Show IAT hides only the IAT; the LT remains unless you also clear Show LT. The defaults for new tests are set in the settings (see Settings, view and help); changing them does not affect existing tests.
The settings for the printout of the first page, the grid lines, the training zones and the second x-axis apply to all tests.
Thresholds
Ergonizer determines all thresholds on the smoothed lactate curve, not on the raw values. The physiological background is explained in Informations sur le diagnostic métabolique de la performance.
Threshold |
How it is determined |
Requirement |
|---|---|---|
The point from which lactate rises disproportionately to the load |
– |
|
The first point above the LT at which lactate exceeds the value at the LT by the lactate constant |
The curve reaches this level |
|
From the point at which the recovery curve falls back to the lactate at the end of exercise, the tangent to the exercise curve; its point of contact is the threshold |
Post-exercise values |
|
The point of the curve with the greatest distance from the straight line between the first and the last point |
– |
|
Dmax,mod |
As Dmax, but the straight line starts at the LT |
LT |
Fixed lactate thresholds |
The power at two fixed lactate concentrations per type of ergometry (for example 2 and 4 mmol/L) |
The curve reaches the level |
The two fixed lactate concentrations can be set for each type of ergometry in the settings (Fixed lactate thresholds, see Settings, view and help).
In the chart, Dmax is shown with the secant and the parallel tangent, and the modified Dmax with the secant from the LT. The Stegmann threshold is shown with its auxiliary lines when the post-exercise course is displayed. With Show fixed lactate thresholds in the plot in the settings, markers at the two fixed lactate concentrations set for the type of ergometry (labelled, for example, P@2.5 mmol/L) replace the IAT and LT markers. A marker only appears if the lactate curve actually passes the concentration.
Notes on the lactate curve
If a test cannot be evaluated completely, the results panel shows a red section with a note and a suggestion what to check:
Lactate curve could not be calculated: no thresholds determined – try stronger smoothing;
Lactate threshold could not be determined;
IAT could not be determined: training zones not calculated – the chart then shows neither the IAT nor training zones;
Implausible lactate values – lactate deviates markedly from the course of the other values; the stage is named. Check the lactate values; outliers can be excluded from the curve via the context menu of the measured point (see Tests and measurement entry). The note is independent of the switch Exclude outliers from the curve and is calculated separately from the suggestion to exclude a value, so it can also appear without that prompt.
Automatic correction of the training recommendations
If the LT of a test is methodically uncertain, Ergonizer corrects the training recommendations: it bases the training zones on a model estimate of the LT and determines the IAT from it with the lactate constant. Stegmann, Dmax and the fixed thresholds remain unchanged. The power profile, the values Max. power over 20min (MMP@20min) and Power output at FTP (60”) on page 1 of the report and training zones based on Critical Power values – for example zones 5a to 5c – follow the corrected values as well. The group analysis shows the corrected LT and IAT, see Group Analysis.
When the correction is applied, the switch Correction with uncertain LT appears in red under the training zones in the results panel, and the report shows the footnote The training load recommendations were corrected due to the atypical course of the lactate curve.. In the report, the heading of the training zone table is marked with an asterisk. Clear the switch to evaluate the test without the correction; the option No automatic correction with difficult LT-estimation on Further information has the same effect. The setting Correction of training zones for uncertain lactate threshold only sets the default for new tests.
Curve smoothing
Under Adjust curve smoothing in the results panel there is one slider each for the Lactate curve, the Lactate curve post exercise (only with recovery values) and the Heart rate curve. The sliders range from 0 to 100; a higher value smooths more strongly. Auto sets the default of 50. The smoothing is saved with the test. Ergonizer recalculates curves, thresholds and training zones shortly after you release a slider.
The smoothing of the lactate curve shifts all lactate thresholds.
The smoothing of the heart rate curve shifts the heart rate at the thresholds and the heart rate ranges.
The smoothing of the post-exercise curve only affects the Stegmann threshold.
With four or fewer lactate values, Ergonizer interpolates between the values instead of smoothing; the post-exercise smoothing requires at least three recovery values.
Comparing with earlier tests
In the Test selection and results overview at the bottom of the main window, the column 2nd test selects the comparison test (see Tests and measurement entry). In the chart it appears as dashed, translucent lactate and heart rate curves, without points, zones and threshold markers. Below the chart, a second x-axis shows arrows from the old to the new position of IAT and LT: green for an improvement, red for a deterioration. The line Changes since names the date of the comparison test.
On page 2 of the report, the table Analysis of results shows the comparison test, the current test and the Difference.
Summary of several tests
Tick further tests of the same type of ergometry in the column Tests for the summary evaluation. They also appear as dashed curves. When more than two tests are ticked, the report gets a page 4 History of measurement data with one column per test (date, age, body weight, LT and IAT with relative power, heart rate and lactate, maximum values and more). The page shows at most the 24 most recent of the ticked tests and says so if more are ticked. Click the column header to tick or clear all tests.
The ticks are not saved; when a subject is loaded, only the test shown and the comparison test are ticked.
Columns of the overview
Choose or right-click a column header of the Test selection and results overview to choose the columns (Columns), to sort, to remove a column or to arrange the columns automatically. The selection is saved for your Windows user account. Among the columns are the race predictions and the measured \(\dot{V}\mathrm{O}_{2}\mathrm{max}\). One of the available columns is the power normalized to a body mass of 78 kg: the relative power multiplied by 78 kg, which makes subjects of different body mass comparable in watts.
Evaluation without lactate
For a test evaluated without lactate (see Tests and measurement entry), the chart shows no lactate curve. The IAT and LT estimated by the model are marked on the heart rate curve; Dmax and the Stegmann threshold are not available. The results panel shows a red warning section.
Result preview and report
shows the report on screen. The toolbar of the preview lets you print, change pages, zoom and show one or two pages; close the preview with the corresponding button. While the preview is open, the side panels are hidden and other functions are not available.
The complete report has the following pages:
Page |
Content |
|---|---|
1 |
Letterhead, description of the test, the main threshold with power, relative power and heart rate, further results depending on the settings, the training intensities and the body data |
2 |
Table of results (with the comparison test), depending on the test the stage table, predictions and training zones |
3 |
The lactate curve (landscape); with the power profile printout, together with the CP curve (portrait). A comment appears here as a box. |
4 |
History of measurement data, only if more than two tests are ticked (landscape) |
In the stage table, each value carries its own unit, for example 13.8 km/h, 140/min, 0.95 mmol/L or 120/80 mmHg. The column Exercise time shows the time from the start of the exercise to the end of the stage, for example 13:57 min. If the table becomes too wide, Total distance is left out first, then Exercise time.
For treadmill, cycle ergometer and running field tests, a one-page Short report with curve, measured values, results and training intensities is available instead. Whether Ergonizer prints the complete or the short report, or asks each time, is set in the settings. For other types of ergometry, Ergonizer points this out once and prints the complete report.
Whether page 4 is printed when more than two tests are ticked is also set in the settings: always (Always print a summary table when more than two records are selected?) or after a question (Ask before printing page 4).
Which threshold appears as the main threshold on page 1 is set with Preferred method for IAT in the settings (IAT, IAT according to Stegmann, Dmax or modified Dmax). If the selected threshold cannot be determined for a test, the IAT is printed. This setting only affects the printout, not the screen.
The content of the report is controlled by:
the Extended print settings in the settings (results on page 1, content of page 2, report length, power profile, training zones), see Settings, view and help;
the options on Further information of each test (predictions, CP curve, \(\dot{V}\mathrm{O}_{2}\mathrm{max}\), percentiles, training scheme), see Tests and measurement entry;
the comment of the test, see Tests and measurement entry.
Logo, letterhead and address come from your licence data.
Print, PDF and e-mail
and (Ctrl+P) open the standard Windows dialogs. The report is printed on A4.
(Ctrl+G) saves the report as a PDF file; the file name suggested is made up of the subject’s name, the test date and the type of test. With Open PDF reader automatically in the PDF settings, the file opens after saving.
saves the reports of a whole group in one PDF file: select the group in the dialog Please select a group and choose the file name (the group name is suggested). Ergonizer prints the most recent test of every subject of the group and, in addition, every test that is itself assigned to the group (see Subjects and groups), each only once, and confirms with PDF file ready and a link to the file. An existing file of the same name is not overwritten; the new file gets a number appended. No test has to be open; afterwards the main window is empty. Like Generate PDF, the command is not available while the preview is open.
sends the report directly from Ergonizer:
Set up the e-mail account once in the settings under PDF settings: Enable PDF by email, the SMTP server, user name, password and port (default 587; port 465 uses SSL, all other ports STARTTLS), and optionally Copy of the findings email to (several addresses separated by
;or,). The sender is the e-mail address from your licence data. See Settings, view and help.Choose . The dialog Email PDF contains the e-mail address of the subject and a text template. In the text, the placeholders
%TEST_DATE%,%GIVEN_NAME%and%NAME%are replaced by the test date and the subject’s name. Save text saves the template for the next e-mails.Click Send email.
An e-mail address entered in the dialog is saved with the subject. Ergonizer confirms the dispatch with The email was sent successfully.. If the PDF cannot be created – for example because an earlier version of the file is still open in a PDF viewer – Ergonizer reports The email was not sent. and nothing is sent.