Working with Ergonizer
Draft
This part of the manual is being written for Ergonizer Version 6 and is not yet complete. Sections may be empty or change without notice.
This part of the manual describes the functions of the Ergonizer application, organized by the areas of the main window and the menus. If you are new to Ergonizer, follow the chapters in order: create a subject, enter a test, evaluate the lactate curve, and derive training zones.
The main window
Ergonizer works in a single main window. All subjects and tests are opened in this window, one test at a time. The window is divided into the following areas:
Menu bar with the menus , , , and (see The menus at a glance).
Toolbars below the menu bar: the Functions toolbar and the Data toolbar. The Power Profile Toolbar appears automatically on the Power Profile tab as soon as a Critical Power evaluation is shown there.
User information panel (top left) with your logo and the name of your institution.
Results panel (left) with the results of the open test. It appears automatically when you open a test or switch to the Lactate curve tab.
Main area with the tabs for the evaluations (see Tabs in the main area). Further panels open on the left when you need them: the panel Analyze group on the Group analysis tab and the panel Maximum predictions from the power profile on the Power Profile tab.
Quick help (right) with the most important next steps (see Quick help).
Test selection and results overview (bottom). It appears as soon as you open or create a subject or test and lists the tests of the subject.
Status bar (see Status bar).
To show a panel or toolbar again after closing it, use the menu. To hide a panel, click × in its title bar. Each time Ergonizer starts, the panels return to this standard arrangement; only the toolbars keep the position you dragged them to.
Tabs in the main area
The main area has up to five tabs, in this order. Which of them are shown depends on the open test and on the modules of your licence.
Shows: the lactate curve of the open test with thresholds and results, see Lactate curve and results.
Available: always.
Shows: power profile, Critical Power and predictions, see Critical Power and power profile.
Available: for tests on the cycle ergometer, treadmill, handbike and rowing ergometer, and for mountain running, roller skiing and running field tests. Not for tests entered as lactate against heart rate or without lactate.
Shows: a comparison of several subjects or tests, see Group Analysis.
Available: always, also without an open test.
Shows: blood glucose during the test.
Available: with the glucose module, for tests that contain glucose values.
Shows: RPE during the test.
Available: with the RPE module, for tests that contain RPE values. Not for tests entered as lactate against heart rate.
When you switch tabs, the quick help, the side panels and the colour of the status bar change with them.
Quick help
The Quick help on the right offers the most useful commands for the current situation:
No test open: Create new record (New subject, New test) and Edit existing data (Edit subject, Open/Edit test, Delete subject).
Test open: Current evaluation with Comment, Preview, Print and Generate PDF.
Power profile tab: additionally Save CP curve.
Preview open: a note that the preview must be closed for all further functions.
If you clear the Always show Quick Help checkbox at the bottom of the quick help, it stays closed when Ergonizer starts. You can open it at any time with (Ctrl+K).
Status bar
From left to right, the status bar shows:
Messages, for example the progress of the background calculation, and otherwise Ready.
Background calculation: Ergonizer evaluates all stored tests once in the background, so that the group analysis can show them immediately. A narrow green bar shows the progress. You can keep working as usual in the meantime.
Values under the mouse pointer: while the mouse pointer is over the lactate curve, the status bar shows the power at this position and the corresponding values (for example heart rate and lactate) of the active test and of the nearest comparison test (in light blue). Right-click in the curve to copy these values.
Update notice: Update available: … appears when a newer version of Ergonizer is available. Click it to open the update dialog; nothing is installed without your confirmation.
Keyboard indicators on the right: CAP, NUM and SCRL show whether Caps Lock, Num Lock and Scroll Lock are on.
The colour of the status bar shows the state of the program: grey when idle, blue during the background calculation, dark orange when a test is loaded and petrol when the group analysis is in front.
A typical workflow
Create a subject with (Subjects and groups).
Enter the measurements with (Tests and measurement entry).
Check the evaluation on the Lactate curve tab (Lactate curve and results) and the derived training zones (Training zones and predictions).
Add a comment if needed (), check the report with and print it or save it as a PDF file (, ).
The quick help on the right always offers the next step.