Training zones and predictions
From the thresholds, Ergonizer derives training zones and further results: the estimated \(\dot{V}\mathrm{O}_{2}\mathrm{max}\), percentiles compared with reference values, and race predictions. This chapter describes how the zones are set up and shown, and where these results appear.
Training categories (zone models)
The training zones are set up under . These settings apply to all tests; changes also affect existing tests whose zones have not been adjusted individually.
- Zone model
Classic (Ergonizer) or ACSM/ESSA. Each model keeps its own names, boundaries and colours.
- Preferred training scheme
1 training zone, 4 training zones (default), 5 training zones or 5 training zones (5a–5c) – the default for new tests. The scheme can be changed for each test, see Training scheme of a test.
Below, the zones are listed for each sport, separately for the Differentiated training zones and the Simple training zone. For each zone you can set:
Description and Abbreviation;
Lower Limit (%) and Upper Limit (%), each as a percentage of a Reference: LT, IAT, IAT according to Stegmann, Dmax, modified Dmax, a fixed lactate concentration (1–12 mmol/L), the power at \(\dot{V}\mathrm{O}_{2}\mathrm{max}\), the maximum performance or the maximum heart rate, and for some sports Critical Power values and FTP (see Critical Power and power profile).
If a reference cannot be determined for a test, Ergonizer uses the LT or the IAT instead. For speed tests, CP-20, CP-30 and FTP come from the power profile. For tests without a power profile (see Critical Power and power profile), zones 5a to 5c and boundaries based on the power at \(\dot{V}\mathrm{O}_{2}\mathrm{max}\) are based on the maximum performance, and boundaries based on CP-20 or FTP on the IAT, also when you drag zone boundaries. Restore defaults resets the zones of the active model, including names and colours.
Default boundaries of the classic model
Each boundary is a percentage of the reference given:
Zone |
Cycling and similar ergometers |
Running, walking, uphill running, roller ski |
|---|---|---|
Zone 1 |
up to 75 % LT |
up to 100 % LT |
Zone 2 |
75–110 % LT |
100 % LT – 95 % IAT |
Zone 3 |
110 % LT – 97 % IAT |
95–101 % IAT |
Zone 4 |
97–106 % IAT |
99–107 % IAT |
Simple training zone |
87–96 % IAT |
87–96 % IAT |
“Cycling and similar ergometers” covers the cycle ergometer, handbike, cross trainer, canoe and the rowing field test. Other sports – for example Sit-Ski, ski mountaineering, swimming and the rowing ergometer – have their own defaults, which you can see in the settings.
For running, zones 3 and 4 overlap deliberately: which of the two applies in this range depends on the duration of the load and the type of interval training.
The ACSM/ESSA model
The ACSM/ESSA model uses the same zones for all sports:
Zone |
Boundaries |
|---|---|
Z1 Very low |
up to 85 % LT |
Z2 Low |
85–100 % LT |
Z3 Moderate |
LT to IAT |
Z4 High |
IAT to 90 % of maximum power |
Z5 Very high |
from 90 % of maximum power, open to the top |
Endurance |
87–96 % IAT |
If the training recommendations of a test were corrected because of an uncertain LT, the zones are based on the corrected thresholds, see Lactate curve and results.
Training scheme of a test
The scheme of a test – one, four or five zones, or five zones with 5a–5c – is set on Further information (Scheme of training recommendations) or in the results panel under Training zones. It determines the bands in the chart, the rows in the results panel and the table in the report. With one zone, the report shows a single individual training recommendation.
Walking and swimming offer one or four zones; all other types of ergometry also the two five-zone schemes (not with the ACSM/ESSA model, which has its own five zones). The upper zones follow the performance-time curve of the power profile (see Critical Power and power profile); if no power profile is available, the maximum performance is used instead:
Scheme |
Upper zones (defaults) |
|---|---|
5 training zones |
Zone 5: from the upper limit of zone 4 (cycling 106 % IAT) to 105 % of the 4-minute performance |
5 training zones (5a–5c) |
Zone 5a as zone 5 above; zone 5b up to 105 % of the 2-minute performance; zone 5c up to 105 % of the 30-second performance |
The zones follow each other without gaps. Boundaries you have changed yourself in the settings are kept.
For walking, uphill running and roller skiing with an increasing slope, the zone boundaries refer to the load converted into an equivalent speed on level ground; the zone table of the report additionally shows the slope.
Recommended training loads
The results panel lists the zones under Recommended training loads, from the lowest to the highest, each with name and abbreviation:
tests in watts: power range and heart rate range;
running and other speed tests: speed in the selected unit, m/s, pace per 1,000 m and heart rate. For treadmill tests with a slope more than 0.5 percentage points above the default treadmill slope (see Settings, view and help), the values are converted to level running;
canoe and rowing field test: boat speed in km/h – for rowing also the power converted to ergometer watts –, pace per 1,000 m and heart rate;
roller ski classic and skating (field tests): speed, pace and heart rate.
Zone 1 is given as an upper limit (“below …”, for the pace “above …”).
Zones in the lactate chart
The zones appear as translucent coloured bands behind the curves. The lowest zone has a frayed edge on the left; the highest zone ends with a jagged edge if its upper limit lies beyond the maximum power. Parts of zone 5 that only begin above the maximum power are shown to the right of an axis break as columns of equal width, with abbreviation and range; they cannot be dragged. The highest zone always keeps a minimum width of 5 % of the maximum power, unless you have dragged its upper limit yourself.
Moving a boundary: drag the boundary between two zones with the mouse. Only its percentage changes; the reference stays the same, so the boundary moves along if the reference changes later (for example with another lactate constant or smoothing). An adjacent boundary at the same position moves with it, but stops before its own other boundary. The heart rate and speed ranges are recalculated. A click without dragging changes nothing.
The change applies to this test only and is saved with it. Reset next to Recommended training loads restores the zones of the settings; it disappears when you drag a boundary back exactly to its default. When you create a new test of the same type of ergometry for the same subject, individually adjusted zones of the comparison test are taken over.
The display is switched in the results panel under Additional settings (for all tests): Show training zones, Show training zone labels, Print training zones and Print training zone labels. All four are on by default.
Zone colours and colour sets
Under , Training intensity colors sets one colour per zone; zones 5a, 5b and 5c have colours of their own (by default orange, rosé and red). The colours apply to all sports of the active zone model, on screen and in print.
A Color set saves the current colours under a name:
Save: type a name and click Save. An existing set of the same name is overwritten.
Select: choose a set from the list and confirm with OK.
Delete: Delete, after a confirmation prompt.
The supplied set Basic setting contains the default colours; it cannot be changed or deleted. Colour sets are saved for your Windows user account.
V̇O2max estimation
Ergonizer estimates the maximum oxygen uptake (\(\dot{V}\mathrm{O}_{2}\mathrm{max}\)) from the maximum performance and the body weight:
Cycle ergometer, handbike, rowing and canoe ergometer, cross trainer: with the ACSM cycle ergometry equation, which adds a power-related part to a part depending on body weight[1]. The rowing field test is calculated in the same way as the rowing ergometer, with the boat speed converted to ergometer power.
Treadmill and other field tests: proportional to the maximum speed reached and the body weight; for treadmill tests with slope, the speed is first converted to level running.
A last stage that was not completed counts proportionally. Height, age and sex are not used. The estimate does not depend on lactate and is therefore also available for evaluations without lactate. No estimate is possible for tests entered as lactate against heart rate.
A \(\dot{V}\mathrm{O}_{2}\mathrm{max}\) measured by spirometry can be entered on Further information (V̇O₂max measured, see Tests and measurement entry). It is shown as a separate value next to the estimate: in the results panel as V̇O₂max (measured) (relative and absolute), on pages 1, 2 and 4 of the report, as a column of the Test selection and results overview and in the Excel export. Predictions and the group analysis use the estimate.
Percentiles
The percentile shows how the IAT of the subject compares with reference values stored in Ergonizer (mean and standard deviation by sex and age group). The reference values are based on about 100,000 measurements of the developer’s own performance diagnostics. For tests in watts, Ergonizer evaluates the power at the IAT in watts and in W/kg, for speed tests the speed. The IAT is always evaluated with the default lactate constant, so that the percentiles of different tests are comparable.
There are reference groups for cycling (general, game sports, competitive endurance athletes) and running (general, power sports, endurance). The sport entered for the subject determines which group is highlighted in the report; if no sport is entered, Ergonizer points this out when printing and shows the general percentiles only.
With Percentiles for race cyclists according to age groups (UCI) in the settings (on by default), the percentile for competitive cyclists is formed against the UCI age categories (U11 to Masters) and shown with the category, for example “(Elite)”. This applies to all pages of the report. If the option is switched off, the percentile refers to the subject’s own age group, also for competitive cyclists.
Percentiles are available where a matching reference exists: for the cycle ergometer (cycling reference) and for treadmill tests, running field tests and uphill running (running reference). They appear in the results panel and are printed in the report if Percentiles on the printout is selected in the settings (Extended print settings) and Percentiles on main page on Further information of the test.
The performance profile of the group analysis uses a different percentile: the rank within your own database, see Group Analysis.
Race predictions
Type of test |
Predictions |
|---|---|
Treadmill, running field test |
1,500 m, 5,000 m, 10,000 m, half marathon, marathon |
Cycle ergometer |
Times for well-known climbs (Hill climbs (predictions)) |
Uphill running |
Times for well-known mountain runs (Mountain or trail running (predictions)) with duration, speed, power and vertical speed; on report page 2 also 10 km and marathon on level ground |
Treadmill walking |
10,000 m, half marathon and marathon |
Roller ski on the treadmill |
10,000 m, half marathon and marathon on level ground, each with time and power in W; on report page 2 also a mountain segment with vertical speed, if one is set up for your licence |
Rowing ergometer, rowing field test |
500 m time and 1,000, 2,000, 5,000 and 6,000 m (report page 2 and Excel export) |
Roller ski classic and skating (field tests) have no predictions.
Running: the predictions are based on statistical models from the speed at the IAT, the maximum speed and the sex and, depending on the distance, heart rate, maximum lactate, height, weight, age, training age and weekly mileage. Ergonizer combines them into one performance-time curve so that the distances match each other. Enter the Training mileage and the Start of training of the subject for the best result; without the weekly mileage, Ergonizer estimates it from the speed at the IAT, and without the start of training, it calculates with a training age of 1 year (see Tests and measurement entry and Subjects and groups). This value also enters the marathon prediction for roller skiing and, through the marathon predictions, the power profile.
Cycling: the climb times combine a performance-time curve with a physical model of the climb (weight of rider and bicycle, air and rolling resistance).
The predictions appear in the results panel. On page 2 of the report they are printed if Race result predictions on printout is selected for the test and Race Performance Predictions in the settings. In the trial version, the results panel shows Only in the full version!.
If a prediction cannot be calculated, a dash (–) appears instead of a time. In the results panel, selecting the row shows the hint Data required for the prediction are missing (e.g., test date or heart rates). below the table. For rowing, the prediction rows are left out if no power curve can be calculated. Times are shown without a leading zero, for example 5:30 min or 1:05:30 h.
On page 2 of the report, the column of the previous test shows its predicted times; the difference is only given if both times are valid. If the previous test was evaluated without lactate, it shows Lactate was not sampled.
For evaluations without lactate, the running predictions show No lactate sampling; the cycling, uphill, walking and roller ski predictions are not available. Walking and roller ski predictions are also left out for tests entered as Lactate vs heart rate. The \(\dot{V}\mathrm{O}_{2}\mathrm{max}\) estimate remains available.
Maximal aerobic speed (MAS)
For treadmill tests and running field tests, Ergonizer can show the maximal aerobic speed as a prediction of the 1,600 m time on grass (MAS (1,600m running pace on grass)): speed, time, pace and heart rate, in the results panel and on page 1 of the report. It requires lactate values. Switch it on in the settings (off by default), see Settings, view and help.
FTP and MMP20 come from the power profile and are described in Critical Power and power profile.